| |
|
|
|
|
| Bio-Medical 2B2 Model |
|
Reliance Instruments Corporation The vacuum autoclave / Sterilizer is designed for strilization of regulated bio- Medical Waste generated from the hospitals for destruction of bacteria and related organism. The equipment produced for bio-medical waste management operate in accordance with the specifications laid down by central pollution control board. The sterilizer is required to handle bio-medical waste of 10-100 kg/per cycle of sterilization is able to perform approx 5 cycles per shift of 8 hours in a day. |
|
|
| |
|
|
|
|
| No of Bed |
Waste Generation(opproximate) |
Model No |
| Up to 50 |
10 kg/hr |
BMW 10 |
| 50-200 |
25 kg/hr |
BMW 25 |
| 300-500 |
50 kg/hr |
BMW 50 |
| 500-800 |
75 kg/hr |
BMW 75 |
| 800 and above |
100 kg/hr |
BMW 100 |
|
| |
|
|
|
|
| The equipment to treat medical waste shall be operated in accordance with the following minimum requirement specified by the pollution control board. |
|
| |
|
|
|
|
| Construction and Features |
|
| |
|
|
|
|
|
The equipment is designed with low chamber floor height for easy loading and unloading. |
|
|
|
|
|
|
|
0.2 micron special filter is used for air to equivalise chamber pressure after drying. |
|
|
|
|
|
|
|
The chamber will have sturdy gasket capable to withstand double the operating pressure |
|
|
|
|
|
|
| Control and monitoring system |
|
| |
|
|
|
|
|
Microprocessor computer system and printer shall be provided for controlling and monitoring the sterilization cycle with real time printer with 18 column giving cycle progression each minute indicating stage of cycle ,Data ,Day, Load Identification number, temperature and pressure or vacuum ,errors and failures, unchangeable date and time record in during each cycle to avoid any tempering by operator |
|
|
|
|
|
|
|
Fully automatic sliding door pneumatically operated with fully advanced programmable logic controller with 80 column full status recording printer. |
|
|
|
|
|
|
|
Rapid Cooling Systems for liquids in bottles and PVC pouches. |
|
|
|
|
|
|
|
N .B the condensate left out with other residues will be fully treated for odorless. |
|
|
|
|
|
|
| Operating parameters for Waste Management(Autoclaves) |
|
| |
|
|
|
|
| 1.Operating temperature |
135° C |
| 2.Operating pressure |
2.2 kg/cm2 or 33psi |
| 3.Residance time for above two parameters |
130 minutes |
| 4.Drying through Vacuum |
20 min. after (sterilization) |
| 5. No of pre- vacuum pulses |
1 to 5 |
|
| |
|
|
|
|
| Specification |
|
| |
|
|
|
|
| Chamber |
SS 316 |
| Jacket |
SS 304 |
| Insulation |
75 mm |
| Insulation Cover |
Powder coated |
| Working Pressure |
32Psi |
| Max Working Temperature |
!37°C |
| Mode of Heating |
Electrical/ External Piped Steam |
| Doors Locking System |
Radial / Sliding / Cam locking and Tongue and Groove System |
| Shape Inside |
Cylendrical/ Rectangular |
| Water Filling |
Manual / Intelligence auto Filling |
| Mode of operation |
Manual mutiport /Valves Optional Micro Controler/PLC /SCADA |
| Safety Device |
Automatic Door Locking System, Safety valve, Water low Cut off Device Etc…. |
| Accessories |
Transfer trolleys, Temperature Recorders, Validation Ports(optional) |
| Filters |
0.5 Micron during Drying. |
| Automatic sequence |
Gravity, Express, Leak Rate Test and Bowie-Dick Test With FO Value Calculation |
| High Vacuum model |
Upto 760mm/Hg with power full vacuum pump 2-4 Pulsing systems |
| Steam temperature |
145 °C Before entering Chamber |
| Pre heater |
For exhaust out let at 150°C |
| Data logging |
Through Serial port printer or computer |
| Tilting |
Chamber pneumatic Tilting Optional. |
|
| |
|
|
|
|